Smoke Detector
Photoelectric ceiling detector for offices, corridors, hotel rooms, classrooms and server areas.
5 products in this range
Detection buys the time that everything else depends on. We supply smoke and heat detectors, manual call points, conventional and addressable control panels, and sounders — and install them as a complete, wired and tested system.
Extinguishers, hydrants and sprinklers all assume somebody knows there is a fire. In an occupied building at night, or a plant room nobody visits for days, that assumption is exactly what fails. A detection and alarm system closes that gap — it notices the fire early and tells everyone in the building at the same moment.
A conventional panel divides the building into zones and tells you which zone is in alarm. For a small or medium building with a clear layout, that is usually enough and it costs less. An addressable system identifies the individual device, which matters when a building is large enough that searching a whole zone would waste time. We will tell you honestly which one your building actually needs.
Detector spacing, ceiling height, airflow and the position of call points along escape routes all affect whether a system works as intended. We install, wire and zone the system, then test it before handover — and the sounder audibility check across the whole building is the part most often skipped elsewhere. Panels and detectors also need periodic testing afterwards, which can be covered under an annual maintenance contract.
Detection is frequently installed alongside sprinkler systems, so that the alarm sounds and the suppression acts together.
The Range
Sizes, capacities and makes vary — tell us about your premises and we will confirm what suits it, along with a price.
Photoelectric ceiling detector for offices, corridors, hotel rooms, classrooms and server areas.
Fixed-temperature or rate-of-rise detector for kitchens, workshops and dusty areas where smoke units would false-alarm.
Break-glass station at exits and staircases so anyone can raise the alarm immediately.
Zone panel that monitors detectors and call points and drives the sounder circuits.
Zone-based panel for small and medium premises where addressable detection is not required.
Where It Is Used
Detection in every room and corridor, because guests are asleep and evacuation is slow.
Early smoke detection across wards and corridors where occupants cannot self-evacuate quickly.
Call points along escape routes and sounders audible across the whole campus, including playgrounds and labs.
Smoke detection through false ceilings and above server racks, with a panel that pinpoints the zone.
Heat detection where dust would false-alarm smoke units, with sounders loud enough over machinery.
Zoned detection through common areas and shafts, with a panel at the security desk.
Questions
Smoke detectors respond earlier and suit clean occupied spaces — offices, corridors, bedrooms and classrooms. Heat detectors suit kitchens, workshops, boiler rooms and dusty areas where cooking fumes, steam or dust would set off a smoke detector repeatedly. Most buildings use a mix of both.
Yes. We install detectors, call points, sounders and the panel, carry out the wiring and zoning, and test the system before handing it over.
In most cases yes — additional detectors or call points can often be added to an existing panel, subject to its capacity and condition. Send us details of the panel you have and we will confirm.
Alarm systems need regular functional testing, because a fault in a detector or a sounder circuit is invisible until the system is actually called on. We can include scheduled testing in a maintenance contract.
Repeated false alarms usually mean the wrong detector type for that location, a device sited too close to an air vent or cooking area, or a unit at the end of its service life. We can look at the installation and advise on the cause rather than simply replacing the device.
Explore More
Portable and trolley-mounted extinguishers for electrical, solid, liquid and gas fire risks.